K4VSO
Product Details
Product Description
To ensure trouble-free, efficient operation, the hydraulic fluid must be carefully selected for the operating conditions during system design. Most mineral-oil-based fluids are suitable to some degree for axial piston components; their use depends on water content, viscosity-temperature behaviour, oxidation and corrosion protection, material compatibility, and air/water separation. Good, reliable filtration is essential for long service life.
Hard-particle contamination of the fluid must not exceed class 9 per NAS 1638, class 6 per SAE, or class 18/15 per ISO/DIS 4406.
At very high fluid temperatures the minimum cleanliness is class 8 per NAS 1638, class 5 per SAE, or 17/14 per ISO/DIS 4406. To select the fluid correctly, the operating temperature relative to ambient must be known: circuit temperature for closed circuits, tank temperature for open circuits. Note: case-drain oil temperature, affected by pressure and speed, is always higher than circuit temperature; no point in the circuit should exceed 90°C.
If extreme operating environments produce temperatures that cannot meet the above conditions, please consult our technical department when ordering. Pump inlet (absolute) pressure must be ≥0.08 MPa; drain (maximum case) pressure is 0.4 MPa absolute, and case pressure must be ≥ the external pressure on the shaft seal. Mounting: the pump/motor case top edge should be below the minimum tank level; specify if mounting above the level is required. Coupling installation: the keyed pump shaft and coupling must be fitted by the hot-mount method—heating the coupling end in an oil bath ≤90°C for 40 minutes, sliding it on easily, quenching with water, then tightening the key set screw. Never strike the shaft when fitting the coupling, and never lift or carry the pump by its shaft.
Technical Features
- K11VSO swash-plate axial piston variable pump designed for open-circuit hydrostatic drives
- Pump flow is proportional to speed and displacement; displacement varies steplessly with the swash angle
- Excellent suction characteristics
- Low noise, long life
- Drive shaft withstands axial and radial loads
- Sandwich design with an excellent power-to-weight ratio
- Short control response time
- Through-drive construction for combined pumps
- Swash-plate angle indicator
- Optional mounting positions
- Can operate on HF fluid with reduced operating parameters
Technical Parameters
| Displacement | 40 | 71 | 80 | 125 | 180 | 200 | 250 | 300 | 355 | 370 | 500 | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Displacement | Vg max | cm3 | 40 | 71 | 80 | 125 | 180 | 200 | 250 | 300 | 355 | 370 | 500 |
| Speed | no max | r/min | 2600 | 2200 | 2200 | 1800 | 1800 | 1700 | 1500 | 1500 | 1500 | 1500 | 1320 |
| Max. speed | no max zul. | r/min | 3200 | 2700 | 2700 | 2200 | 2100 | 2000 | 1800 | 1700 | 1700 | 1700 | 1600 |
| Flow | nE=1500r/min | L/min | 60 | 107 | 121 | 186 | 270 | 283 | 375 | 450 | 532 | 555 | 750 |
| Power | nE=1500r/min | kW | 35 | 62 | 70 | 109 | 158 | 166 | 219 | 262 | 311 | 324 | 437 |
| Torque | ng max | Nm | 64 | 113 | 113 | 199 | 286 | 286 | 398 | 478 | 564 | 588 | 795 |
| Weight | kg | 39 | 53 | 53 | 88 | 102 | 102 | 184 | 184 | 207 | 207 | 320 | |
| Max. axial force | N | 600 | 800 | 800 | 1000 | 1400 | 1400 | 1800 | 2000 | 2000 | 2000 | 2000 | |
| Max. radial force | N | 1000 | 1200 | 1200 | 1600 | 2000 | 2000 | 2000 | 2200 | 2200 | 2200 | 2500 | |